17th Edition Cable Sizer - Cable Size Calculator Login

Listing Results 17th Edition Cable Sizer - Cable Size Calculator Login

About 19 results and 7 answers.

‎17th Edition Cable Sizer - Cable Size Calculator on the

4 hours ago Sep 29, 2014 . Simple, fast and reliable. 17th edition cable sizer performs cable Calculation for AC circuits in line with British Standard 7671:2008 (2011) IEE Wiring regulations, without having to lookup the relevant tables. Simply enter the circuit parameters, hit calculate, and 17th edition cable sizer does the work for you by selecting the correct cable ...

Show more

See More

17th Edition Cable Sizer – Cable Size Calculator iPhone

5 hours ago 17th Edition Cable Sizer – Cable Size Calculator. Cable size calculation done completely and accurately in seconds, providing detailed results with all correction factors used. Perform an automatic calculation where the circuit is sized automatically or enter fixed sizes to run a calculation check on an existing design.

Show more

See More

17th Edition Cable Sizer - Cable Size Calculator - Free

12 hours ago Sep 29, 2014 . Download 17th Edition Cable Sizer - Cable Size Calculator for iOS to cable size calculation done completely and accurately in seconds, providing detailed results with …

Show more

See More

CPC Sizing Tool - myElectrical

8 hours ago Protective Conductor Cross Sectional Area. (BS 7671/ IEE Wiring Regulations 17th Edition) Use 543.1.1 or 543.1.4 for size (543.1.3 is manatory if short circuit considered in main cable size). Mimium size 2.5 mm 2 if mechanically protected and 4 mm 2 if not. Use most onerous fault current/operating time and largest line conductor csa.

Show more

See More

Cable Size Calculator Find the size of your Wire/Cable

12 hours ago Cable (or conductor) estimating is the way toward choosing suitable sizes for electrical power cable conductors. Cable sizes are typically depicted as far as cross-sectional territory, American Wire Gauge (AWG), or kcmil, contingent upon the geographic district. The correct measuring of cables is essential to guarantee that the cable can: Work ...

Show more

See More

Cable Calculator - BS 7671 17th Edition Cable Calculator

2 hours ago BS 7671 17th Edition Cable Calculator... A cable size calculator Application, that allows electricians / Engineers to quickly calculate the size of a single circuit, in accordance with BS 7671: 2008 Amd 1 .. 2011. The App is divided into 2 sections.... The first section allows for calculation of phase conductor.

Show more

See More

Cable Calculator - Cable Sizing & Selection Eland Cables

12 hours ago How to find the size of a cable? Cable size calculator to aid specification of cables to British Standard BS7671 and International standard IEC 60364-5-52. Use the cable calculator to add your installation details for sizing guidance and cable type suggestions. Full technical support available.

Show more

See More

17th Edition Cable Sizer - YouTube

12 hours ago Cable size calculation done completely and accurately in seconds, providing detailed results with all correction factors used. Perform an automatic calculati...

Show more

See More

17th Edition Cable Sizer : Amazon.co.uk: Apps & Games

12 hours ago Simple, fast and reliable. 17th edition cable sizer performs cable Calculation for AC circuits in line with British Standard 7671:2008(2011) IEE Wiring regulations, without having to lookup the relevant tables. Watch the video for a full demonstration of the features available.

Show more

See More

IET Forums - BS7671 and calculating cable size

6 hours ago Oct 31, 2003 . The length of the run from the fuse is 20m and for half this run, the cable is to be clipped to wall surfaces. For the remainder it shares a cable tray, touching two similar cables across the top of a boiler room the ambient temperature is 50 degrees C. Select an appropriate BS88 fuse rating and suggest the size of cable that my be appropriate.

Show more

See More

Cable sizing for safety and in accordance with the 17th

1 hours ago Mar 01, 2010 . It is very important to note, when using cable sizing calculators that recommended cable sizes are based upon information provided by the installer or user and are intended only as a guide. For example, calculation might be derived from BS7671:2008 Installation method C (Clipped Direct), for cable types BS5467 and BS6724 - with the voltage drop ...

Show more

See More

Cable Tray Size Calculator - CNET Download

3 hours ago 17th Edition Cable Sizer - Cable Size Calculator. $2.99. Cable size calculation done completely and accurately in seconds, providing detailed results with all correction factors used. Perform an ...

Show more

See More

Welcome to Doncaster Cables - Technical Help

1 hours ago 4. Input the length of your cable run 5. Choose the method of installation how the cable is going to be installed 6. Press calculate and your cable sizes will be calculated. Our calculator now lists different cable types, so by scrolling down the list you are able to see how different cable types may have different sizes for the same set of ...

Show more

See More

Calculating cable size is a bit of a pain?

10 hours ago Aug 08, 2015 . Once it’s installed, all you need to do is enter the cable type, ref method, the maximum load in kW or watts and the cable length in metres. The app will instantly calculate and display the minimum cable size, the voltage drop - in volts and as a percentage - and the load current in amps. To save you time, the supply voltage defaults to 230 V ...

Show more

See More

Cable Size Calculator AS/NZS 3008 jCalc.NET jCalc.net

1 hours ago Cable impedance calculation. The impedance is calculated as: Z c = R c 2 + X c 2. This method calculates the impedance for the worse case power factor, i.e. when the cable and load power factor is the same. The cable sizing calculator uses the resistance Rc from Table 35 in AS/NZS 3008-2017 .

Show more

See More

Cable Calculator

8 hours ago A cable size calculator designed for use by electricians, electrical designers and engineers to quickly size a single circuit to BS 7671:2008 (17th Edition) Features include:- …

Show more

See More

SWA Cable Calculator - Electrical Trader

6 hours ago This cable calculator is set for Installation method C (Clipped Direct), for cable types BS5467 and BS6724 SWA (Steel wire armoured cable) and is based on the voltage drop selected at 230V single phase and 400V three phase. If you need any further help with sizing your cable please call one of our team on 01244 288138.

Show more

See More

Cable Sizing Calculator - IFSEC Global

5 hours ago Sep 14, 2009 . The calculator is available free of charge by registering at the company’s website. The cable specification programme starts with the selection of the desired cable from a drop-down box, the desired phase of the supply, whether it is single or multi-core and if the cable is to be buried. The calculator then moves on to installation method and ...

Show more

See More

Cable Calculator - Cleveland Cable

6 hours ago Set Load to 4x rated power/current for motor applications. Allowable Voltage Drop (%) Cable Length (m) Calculate Min. Cable Size. Required Cable Size (mm2) Voltage Drop (volts) Percentage Drop (%) …

Show more

See More

Frequently Asked Questions

  • Is there a calculator for cable sizing?

    Eland Cables' Cable Calculator can help you determine the most appropriate cable size for your installation against British and IEC standards. Complete the sections below to calculate your results.

  • Which is the best app to calculate cable size?

    Megger has an app called Cable Calc+, which does exactly what you want. Better still, it’s absolutely free to download and use, and it even works without an Internet connection. Once it’s installed, all you need to do is enter the cable type, ref method, the maximum load in kW or watts and the cable length in metres.

  • What do you call the length of a cable?

    Cable Run- Cable run is the length of the cable, you are going to use while wiring your house or workplace. Make sure you check the resistance and thickness of the wire. Cable Size Calculation Formulas

  • How does the AS / NZS 3008 cable size calculator work?

    The cable sizing calculator uses the resistance Rc from Table 35 in AS/NZS 3008-2017 . The reactance for single core cables is selected from the flat, touching column in from Table 30 in AS/NZS 3008.

  • Is there a calculator for cable sizing?

    Eland Cables' Cable Calculator can help you determine the most appropriate cable size for your installation against British and IEC standards. Complete the sections below to calculate your results.

  • Which is the best app to calculate cable size?

    Megger has an app called Cable Calc+, which does exactly what you want. Better still, it’s absolutely free to download and use, and it even works without an Internet connection. Once it’s installed, all you need to do is enter the cable type, ref method, the maximum load in kW or watts and the cable length in metres.

  • How big should a mimium cable be for a short circuit?

    Use 543.1.1 or 543.1.4 for size (543.1.3 is manatory if short circuit considered in main cable size). Mimium size 2.5 mm 2 if mechanically protected and 4 mm 2 if not. Use most onerous fault current/operating time and largest line conductor csa.

Have feedback?

If you have any questions, please do not hesitate to ask us.